CBRN Full Body Suit

Contact Us For Pricing and Demo

SKU:
DFB

CBRN Full Body Suit

This CBRN Full Body Suit offers full chemical protection with protection from Alpha, Beta and Gamma Radiation. 

 

The only suit to provide total protection for CBRN threat

  • Gamma
  • Beta
  • Alpha
  • X-Ray
  • CWA - chemical warfare agents
  • Industrial Chemicals
  • Heat stress

Made in the USA!

 

CBRN Full Body Suit SPECS:

 

The lead equivalence of a sample (B) from RST was tested using the following equipment and procedure:

 

X-Ray Generator: GE MPH

X-Ray Tube: GE BE

kVp Meter: RadCal Accu-kv

Dosimeter: Fluke 10100AT TRIAD

 

The kVp accuracy was verified by a RadCal Accu-kv kVp meter. The transmission of the sample was measured with a Fluke 10100AT TRIAD dosimeter and a 150cc high sensitivity ion chamber. The lead equivalent thickness of the sample was calculated using Equation A.3 in NCRP report #147. The values of alpha, beta and gamma for lead at each kVp were taken from the same report.

 

The results are reported below:

 

Set

kVp

Measured

kVp

Alpha

Beta

Gamma

Exp

w/o

Sample

Mean

mAs

Exp

w/

Sample

Mean

B

% Attenuation

Lead Equivalence (mm)

50

50.1

8.801

27.28

0.2957

230

230

100

9.33

9.3

0.0406

95.94

0.125

60

60.2

6.951

24.89

0.4198

344

344

100

25.1

25.1

0.073

92.70

0.124

70

70.6

5.369

23.49

0.5881

236

236

50

25

25.0

0.1059

89.41

0.131

79

79.7

4.04

21.69

0.7187

296

296

50

41.3

41.3

0.1395

86.05

0.137

89

90

3.067

18.83

0.7726

368

368

50

64.6

64.6

0.1755

82.45

0.141

98

99.9

2.5

15.28

0.7557

436

436

50

88.6

88.6

0.2032

79.68

0.150

108

110.3

2.296

11.7

0.6827

517

517

50

118.6

118.6

0.2294

77.06

0.160

118

120.5

2.246

8.95

0.5873

600

600

50

152

152.0

0.2533

74.67

0.168

127

129.5

2.17

7.094

0.4909

677

677

50

184.4

184.4

0.2724

72.76

0.178

 

 Schedule your demo today!